The Roswell Report: Fact versus Fiction in the New Mexico Desert was published in 1995 by Headquarters United States Air Force. It was written in response to Representative Steven H. Schiff's request and a General Accounting Office audit, and it contains Col. Richard L. Weaver's report and 1st Lt. James McAndrew's synopsis, along with attachments, appendices and photographs. The report says researchers found no evidence of an extraterrestrial craft or crew. It concludes that the 1947 debris came from a Project MOGUL balloon train.

  • p. 5 …Also, Robert "Gus" Bell contributed with his attractive art work; Richard Wolf provided invaluable computer expertise…
  • p. 108 …A. Beck, and Lt Colonel John H. Bell arrived !ro.111 Headquar- ters, Strategic Air Cor…
  • p. 259 …If it did, it didn't ring a bell. Q: And no one mentioned it to…
  • p. 401 …It is r:ry belle! tr..at a larse rocket or Jet propul·- sion :notor passing…
  • p. 475 …It is possible, using a bell jar for flight-similitude studies, to arrange switches so that…
  • p. 476 …The first is that a leak of air into the bell jar is pennitted at a…
  • p. 478 …Other equipment which has been tested in the bell jar and the cold chamber includes the…
  • p. 519 …The most comprehensive tests of this~ were made with two Olland-cycles in the same bell…
  • p. 910 …The following equip- ment is required for the calibration: · Vacuum pump Bell jar Base plate with…
  • p. 922 …The in- strument is placed in a bell jar and the air evacuated. The pressure is…
By knowing the altitude of release and counting the number of
switches from conductor to insulator, the position along the
the commutator is kno'Wtl. This in turn is calibrated to give
pressure values, from which the altitude may be computed.
This system was not suitable for floating balloons because
(1) only 70 to 90 discrete contacts are provided to cover the
entire atmospheric pressure range; this means that the best
readability obtainable with this system is about ~10 millibars.
(2) When the balloon oscillates about a floating level, the fre-
quent changes from one contact to another give ambiguous readings,
since the number of discrete resistances used is limited.
For circuit details of this unit, see T.E. Sig. 165 and the
Weather Equipment Technician's Manual.
(2) Specially Coded Radiosonde Modulators
To remove the ambiguity of altitudes reported by the system
above, extra resistances were introduced into the circuits
of those contacts near the floating level; thus, each contact
gives a distinctive frequency and each pressure (altitude)
can be clearly distinguished.
In this system, there still remains the lack of resolution or
sensitivity inherent in the modulator with 70 to 90 contacts.
(3) Olland-Cycle Modulator
To improve the sensitivity of the pressure measurements, an
Olland-Cycle (chronometric) pressure modulator ~s developed.
Seen in Figure 30, the modulator contains a standard Signal
Figure 30. Olland-Cycle pressure modulator.