CONFIDENTIAL
311
112:06:10
CC
A pleasant good morning to you from Canary. We have a couple of things for you. Have you done a fuel cell purge recently?
112:06:14
P
It's overdue in the flight plan but we thought we'd wait until we were over somebody.
112:06:19
CC
Okay. Very good. We're ready for you now, whenever you are.
112:06:22
P
Okay. One purge coming down.
112:09:09
CC
VII, Canary. Would you put your Quantity Read switch to FUEL CELL H₂?
112:09:13
P
Roger. FUEL CELL H₂.
112:09:14
CC
Roger.
112:11:11
P
Purge complete, Canary.
112:11:13
CC
Roger. We need some readouts here on the ground. You can keep it there on FUEL CELL H₂.
112:11:19
P
Okay.
112:11:20
CC
What are you reading up there on quantity and pressure?
112:11:28
P
About 82 percent and 400 psi.
112:11:33
CC
Roger. Okay. You want to go back to 1 to FUEL CELL O₂ on the Quantity Read switch?
112:11:44
P
Right. We are at FUEL CELL O₂.
112:11:47
CC
Roger.
112:12:08
CC
What are you reading, quantity and pressure, please?
112:12:15
P
About 77 percent, Ed. 720.
112:12:20
CC
Roger. I copy. Now Quantity Read switch to ECS O₂.
112:12:42
CC
Quantity and pressure.
CONFIDENTIAL