Documents / Report
Defense Intelligence Reference Document Technological Approaches To Controlling
Defense Intelligence Agency · 36 pages · text from the file's own layer
This Defense Intelligence Reference Document from the Defense Intelligence Agency, dated 23 March 2010, was produced under the Advanced Aerospace Weapon System Applications (AAWSA) Program. It surveys invasive and noninvasive brain-machine interface technologies for controlling external devices without limb-operated interfaces. The technologies covered include EEG, MEG, fMRI, NIRS, and implanted electrode arrays. It concludes that noninvasive electrical monitoring is the most promising near-term approach. In the long term, it favors invasive single-neuron cortical connections that use optical stimulation or chip-based arrays.
“The Times”18 pages
- p. 5 UNCLASSIFIED/)' Pett :SPPll!ltllt '11815 .,.LY
Technological Approaches to Controlling External Devices
in the Absence of…
- p. 8 …Neurons
require some time to reset between firings, nominally the duration of the pulse for that…
- p. 10 UNCLASSIFIED/ ,erg A gffllil.t.L '1181!! 8HLY
The brain activity mentioned above is a complex…
- p. 13 …The response time to
execute a command using these systems is measured in seconds. The results…
- p. 14 …application, the fact that 100 IT is about 100 million times smaller than the Earth's…
- p. 15 …In
current MRis, these gradient fields are produced with electromagnets, and the series of
time-dependent…
- p. 18 …prior to implantation, and then the tasks are
repeated multiple times while muscle action and cortical…
- p. 19 …the
movement control algorithm is similar to a population vector in that movement at each
time…
- p. 20 UNCLASSIFIED/,'P81il 8PPll!ltllt ~81!! 8HLV
Japan in real time. Using visual feedback to the monkey…
- p. 21 …employed to allow for real-time bidirectional interface with the nervous system. After
several modifications, Fetz…
- p. 22 …understand the brain, its regions of activity and how those
area correlate to real time stimulation…
- p. 25 …FOV=60x60mrn 7 • Experiment time=512 s. (B) (Top) Microelectrode array
used in the study. (Bottom…
- p. 28 …Movement times to target were on the order of 1-2 seconds with up to 75…
- p. 29 …This trial lasted 3 months before the physical connection between
the nerve and the microarray deteriorated…
- p. 31 …Also beneficial to reaction time is the combined EMG EEG devices
mentioned above since the pathways…
- p. 32 …Proof of principle studies in this technology could emerge at any time, and given
the demonstrated…
- p. 34 …time. J Cogn Neurosci 2002 Nov
15; 14(8): 1200-14.
" Hatsopoulos NG, Donoghue JP. The…
- p. 36 …Targeted muscle reinnervation for real-
time myoelectric control of multifunction artificial arms. JAMA 2009 Feb 11…
23 March 2010
ICOD: 1 December 2009
DIA-08-1003-012
UNCLASSIFIED/ ;'FOA UFFl@lillt ~91!!! 8HLY
Defense
Intelligence
Reference
Document
Acquisition Threat Support
Technological Approaches to
Controlling External Devices in
the Absence of Limb-Operated
Interfaces
UNCLASSIFIED//FUR: UFFl@Jgtal: W&li UHl:Y
Not linked to a story yet.
About this file
Report, from the dia collection. The PDF is mirrored here; the original link is under it. 36 pages are in the text index: search them above, or from the library's search.