Documents / Report

Defense Intelligence Reference Document Technological Approaches To Controlling

Defense Intelligence Agency · 36 pages · text from the file's own layer

This Defense Intelligence Reference Document from the Defense Intelligence Agency, dated 23 March 2010, was produced under the Advanced Aerospace Weapon System Applications (AAWSA) Program. It surveys invasive and noninvasive brain-machine interface technologies for controlling external devices without limb-operated interfaces. The technologies covered include EEG, MEG, fMRI, NIRS, and implanted electrode arrays. It concludes that noninvasive electrical monitoring is the most promising near-term approach. In the long term, it favors invasive single-neuron cortical connections that use optical stimulation or chip-based arrays.

  • p. 5 UNCLASSIFIED/)' Pett :SPPll!ltllt '11815 .,.LY Technological Approaches to Controlling External Devices in the Absence of…
  • p. 8 …Neurons require some time to reset between firings, nominally the duration of the pulse for that…
  • p. 10 UNCLASSIFIED/ ,erg A gffllil.t.L '1181!! 8HLY The brain activity mentioned above is a complex…
  • p. 13 …The response time to execute a command using these systems is measured in seconds. The results…
  • p. 14 …application, the fact that 100 IT is about 100 million times smaller than the Earth's…
  • p. 15 …In current MRis, these gradient fields are produced with electromagnets, and the series of time-dependent…
  • p. 18 …prior to implantation, and then the tasks are repeated multiple times while muscle action and cortical…
  • p. 19 …the movement control algorithm is similar to a population vector in that movement at each time…
  • p. 20 UNCLASSIFIED/,'P81il 8PPll!ltllt ~81!! 8HLV Japan in real time. Using visual feedback to the monkey…
  • p. 21 …employed to allow for real-time bidirectional interface with the nervous system. After several modifications, Fetz…
  • p. 22 …understand the brain, its regions of activity and how those area correlate to real time stimulation…
  • p. 25 …FOV=60x60mrn 7 • Experiment time=512 s. (B) (Top) Microelectrode array used in the study. (Bottom…
  • p. 28 …Movement times to target were on the order of 1-2 seconds with up to 75…
  • p. 29 …This trial lasted 3 months before the physical connection between the nerve and the microarray deteriorated…
  • p. 31 …Also beneficial to reaction time is the combined EMG EEG devices mentioned above since the pathways…
  • p. 32 …Proof of principle studies in this technology could emerge at any time, and given the demonstrated…
  • p. 34 …time. J Cogn Neurosci 2002 Nov 15; 14(8): 1200-14. " Hatsopoulos NG, Donoghue JP. The…
  • p. 36 …Targeted muscle reinnervation for real- time myoelectric control of multifunction artificial arms. JAMA 2009 Feb 11…
UNCLASSIFIED/ /PIHi: 8fflll.t.k YE&i 811L>C
based on skin movement using technology similar to the operation of GPS. This system
would have the same inherent problem of signal conduction through tissue from all
directions. The key indicator of a future advance in EEG technology would be a study
showing noninvasive spiking or ERP signal detection from a coherent group of less than
10,000 neurons. Until progress in localization on this order is demonstrated, EEG-only
devices will remain low bit rate application technologies.
EEG-only sensor control of devices has been pursued with the supposition that signal
transmission directly from the motor cortex will outperform conventional mechanical
operation because the signal transmission delay between the neocortex and muscles in
the extremities will be augmented via a physical circuit. While this is true, the inherent
assumption that complex mechanical interface operation can be replaced with a 1
bit/second low-delay control pathway is incorrect for naturalistic environments. The
millions of channels of two-way communication between the extremities and the brain
naturally present will control naturalistic mechanical devices far better, and provides
the ability to react to an ever-changing environment. Adding significant computer
control and relegating the motor cortex to a supervisory role of low data bandwidth
could have benefits and is a possible path to real-world improved reaction time
application. Also beneficial to reaction time is the combined EMG EEG devices
mentioned above since the pathways between the brain and facial muscles are far
shorter than those to the extremities.
NONINVASIVE BOLD-BASED DEVICES
The detection resolution of hemodynamic responses using fMRI and NIRS type
technologies is expected to improve in the near, medium, and far terms. NIRS has been
deployed in naturalistic experiments, specifically, automobile driving, and it is
reasonable to envision such systems becoming small enough to wear in the medium to
far term. The limiting issue with BOLD technologies is that the detectable response is
delayed several seconds from neuronal firing, greatly limiting the cognitive control
applications available to these technologies. Progress in localization to below 0.5 mm 3
in a mobile device could indicate the possibility of high bit transfer rates with the use of
state vector machines, albeit with the inherent delay of the physiology. Until the
localization and portability issues are addressed in tandem, BOLD-only devices are
unlikely to be used for commercial cognitive control interfaces.
The vast majority of experiments in fMRI utilize the General Linear Model (GLM) and
something akin to a canonical hemodynamic response. There exists significant
physiological noise in these data analyses that are traditionally filtered out. The
differential results from Independent Component Analysis (ICA) and GLM analysis of the
same data sets indicate that there may be additional circulatory response mechanisms
with faster onsets than typical BOLD. Future studies indicating that filtering or analysis
methods may be ignoring important detectable signals that have inherently faster
response times would provide a breakthrough path for hemodynamic response
technologies. The current research to monitor on this matter is the technology known
as Inverse MRI which can capture high temporal resolution (100 frames a second for
single slices) T2* variations.
25
UNCLASSIFIED,'~P8"1 8PPll!l"'I! l!l!il! 8111!¥

Not linked to a story yet.

About this file

Report, from the dia collection. The PDF is mirrored here; the original link is under it. 36 pages are in the text index: search them above, or from the library's search.