This Defense Intelligence Reference Document from the Defense Intelligence Agency, dated 23 March 2010, was produced under the Advanced Aerospace Weapon System Applications (AAWSA) Program. It surveys invasive and noninvasive brain-machine interface technologies for controlling external devices without limb-operated interfaces. The technologies covered include EEG, MEG, fMRI, NIRS, and implanted electrode arrays. It concludes that noninvasive electrical monitoring is the most promising near-term approach. In the long term, it favors invasive single-neuron cortical connections that use optical stimulation or chip-based arrays.

  • p. 5 UNCLASSIFIED/)' Pett :SPPll!ltllt '11815 .,.LY Technological Approaches to Controlling External Devices in the Absence of…
  • p. 8 …Neurons require some time to reset between firings, nominally the duration of the pulse for that…
  • p. 10 UNCLASSIFIED/ ,erg A gffllil.t.L '1181!! 8HLY The brain activity mentioned above is a complex…
  • p. 13 …The response time to execute a command using these systems is measured in seconds. The results…
  • p. 14 …application, the fact that 100 IT is about 100 million times smaller than the Earth's…
  • p. 15 …In current MRis, these gradient fields are produced with electromagnets, and the series of time-dependent…
  • p. 18 …prior to implantation, and then the tasks are repeated multiple times while muscle action and cortical…
  • p. 19 …the movement control algorithm is similar to a population vector in that movement at each time…
  • p. 20 UNCLASSIFIED/,'P81il 8PPll!ltllt ~81!! 8HLV Japan in real time. Using visual feedback to the monkey…
  • p. 21 …employed to allow for real-time bidirectional interface with the nervous system. After several modifications, Fetz…
  • p. 22 …understand the brain, its regions of activity and how those area correlate to real time stimulation…
  • p. 25 …FOV=60x60mrn 7 • Experiment time=512 s. (B) (Top) Microelectrode array used in the study. (Bottom…
  • p. 28 …Movement times to target were on the order of 1-2 seconds with up to 75…
  • p. 29 …This trial lasted 3 months before the physical connection between the nerve and the microarray deteriorated…
  • p. 31 …Also beneficial to reaction time is the combined EMG EEG devices mentioned above since the pathways…
  • p. 32 …Proof of principle studies in this technology could emerge at any time, and given the demonstrated…
  • p. 34 …time. J Cogn Neurosci 2002 Nov 15; 14(8): 1200-14. " Hatsopoulos NG, Donoghue JP. The…
  • p. 36 …Targeted muscle reinnervation for real- time myoelectric control of multifunction artificial arms. JAMA 2009 Feb 11…
UNCLASSIFIED,';'F811. 8FFll!l*le 1!1!11!! 8111!Y
The remainder of discussion concentrates on the surveyed studies into five technology
areas, and listing their advantages and disadvantages, as well as their critical barriers
to further development and likely future paths of research.
NONINVASIVE ELECTRICAL DEVICES
The current state-of-the-art BMI devices that have shown the most promise in the near
term utilize muscle amplification of the neural signal. This is the result of commercial
investment in development. These primarily EMG based systems are noninvasive
connections to existing or constructed nerve-muscle pairs. Neurally operated
prosthetics have been demonstrated such as the artificial hand. Decoding algorithms
are nearly as fast as muscle response itself at selecting 1 of 10 actions. Commercial
products for entertainment are available for normal, healthy consumers. These
entertainment devices contain few sensors but make use of more complex decoding
algorithms. All sensors don't just turn on and off, rather they can relay amplitude,
polarity, and frequency of muscle action, as well as detect underlying spiking signals
from neurons. This combination, along with algorithms developed from a support vector
machine, will allow device selection of many more actions than the simple binary
combinatorics of the number of sensors. The gaming market will drive this noninvasive
technology in the next 5 years with advances in signal processing from current sensors.
The EMG based systems can be scaled to a large number of sensors for a more complex
control task. It has been demonstrated with amputees the feasibility to move existing
nerves around to control existing muscles. There has not been a study yet to explore
how many nerve-muscle pairs may be available for such use in a normal human, with
or without reinnervation. Such a study could be done theoretically based on current and
near term work with patients. The longer term for EMG will likely evolve toward very
small, wireless chronic implants that operate near the skin surface and are easy to
install and remove.
Devices based solely on noninvasive detection of EEG signals from the cortex in normal,
healthy individuals are unlikely in the next 5 years. This is primarily because of muscle
noise filtering issues which will need to be solved through development of better EMG
sensors and detection algorithms mentioned above. Even though such devices have
been shown to work in laboratory settings, moving them to the arbitrary conditions in
naturalistic settings introduces significant complication to signal detection and filtering
that greatly limits the information transfer bandwidth to a fraction of the target 5
bits/sec. Also an issue is the origin of surface EEG signals, which are still under
theoretical study even after 80 years. Some of the frequency bands directly related to
spiking activity in axons are somewhat understood, but the whole of the signals contain
many transients that are likely the more interesting and possibly more robust parts of
brain activity. In the medium to long term, many applications are envisioned in surface
or near surface detection of cortical spiking activity or ERP, once the background
separation issue in naturalistic environments is addressed. However, these signals still
require localized coherent firing of tens of thousands of neurons, a biological
requirement that has limited the information transfer rates of these techniques to 1
bit/sec or less, which is well below target rates but could be useful for some
applications.
One can suppose an ultra-high density EEG, thousands of sensors with wireless micro
probes embedded subcutaneously that track electrical activity and relative location
24
UNCLASSIFIED/ ;CFQlil 8FFIIIAI!: ~:!II!! 8HLY

Not linked to a story yet.

About this file

Report, from the dia collection. The PDF is mirrored here; the original link is under it. 36 pages are in the text index: search them above, or from the library's search.