Documents / Report

Defense Intelligence Reference Document Technological Approaches To Controlling

Defense Intelligence Agency · 36 pages · text from the file's own layer

This Defense Intelligence Reference Document from the Defense Intelligence Agency, dated 23 March 2010, was produced under the Advanced Aerospace Weapon System Applications (AAWSA) Program. It surveys invasive and noninvasive brain-machine interface technologies for controlling external devices without limb-operated interfaces. The technologies covered include EEG, MEG, fMRI, NIRS, and implanted electrode arrays. It concludes that noninvasive electrical monitoring is the most promising near-term approach. In the long term, it favors invasive single-neuron cortical connections that use optical stimulation or chip-based arrays.

  • p. 5 UNCLASSIFIED/)' Pett :SPPll!ltllt '11815 .,.LY Technological Approaches to Controlling External Devices in the Absence of…
  • p. 8 …Neurons require some time to reset between firings, nominally the duration of the pulse for that…
  • p. 10 UNCLASSIFIED/ ,erg A gffllil.t.L '1181!! 8HLY The brain activity mentioned above is a complex…
  • p. 13 …The response time to execute a command using these systems is measured in seconds. The results…
  • p. 14 …application, the fact that 100 IT is about 100 million times smaller than the Earth's…
  • p. 15 …In current MRis, these gradient fields are produced with electromagnets, and the series of time-dependent…
  • p. 18 …prior to implantation, and then the tasks are repeated multiple times while muscle action and cortical…
  • p. 19 …the movement control algorithm is similar to a population vector in that movement at each time…
  • p. 20 UNCLASSIFIED/,'P81il 8PPll!ltllt ~81!! 8HLV Japan in real time. Using visual feedback to the monkey…
  • p. 21 …employed to allow for real-time bidirectional interface with the nervous system. After several modifications, Fetz…
  • p. 22 …understand the brain, its regions of activity and how those area correlate to real time stimulation…
  • p. 25 …FOV=60x60mrn 7 • Experiment time=512 s. (B) (Top) Microelectrode array used in the study. (Bottom…
  • p. 28 …Movement times to target were on the order of 1-2 seconds with up to 75…
  • p. 29 …This trial lasted 3 months before the physical connection between the nerve and the microarray deteriorated…
  • p. 31 …Also beneficial to reaction time is the combined EMG EEG devices mentioned above since the pathways…
  • p. 32 …Proof of principle studies in this technology could emerge at any time, and given the demonstrated…
  • p. 34 …time. J Cogn Neurosci 2002 Nov 15; 14(8): 1200-14. " Hatsopoulos NG, Donoghue JP. The…
  • p. 36 …Targeted muscle reinnervation for real- time myoelectric control of multifunction artificial arms. JAMA 2009 Feb 11…
UNCLASSIFIED/ ;<F&lil: 8FFI1iltlit '11815 8HL'/
microelectric design of chronic neural implants. In 2006, Fetz et al. illustrated an
intracranial operated neural implant that could function as neural prosthetic to assist
upper limb movement for individuals that suffered from spinal cord injuries. The
intriguing part of the Fetz design is its ability to function as an autonomous battery
operated device. This is a departure from traditional BMI devices that are cumbersome
and difficult to operate. Clearly this is a step forward in the development of microwire
electrode design applications (Reference 44). Figure 5 illustrates the schematic flow
chart of the Fetz MEMS neurochip, also called a programmable system-on-chip (PSoC)
architecture.
Programmable System on Chip Architecture
IR module ( Memory J (Memory J
l l l
(__P_;_;_o"-t--J---• I
l !
Secor~dary
PSoC
------
l
W~ £.e~ ~ ~
VJ '= ~
~ "
~ ry ll llM,crow,re elec1<0des EMG electrodes
Figure 5. Schematic of the Neurochip Functional Blocks. Parallel Psoc microcontrollers record neural and
muscle signals to independent memory modules. Primary PSoC also controls a constant-current stimulator circuit
and communicates via IR to a PC or hand-held POA. (Reference 44)
Traditional PSoC designs operate on a high power consumption and short battery life of
radiotelemetry systems (Reference 46). In the Fetz study, researchers implanted
electronic devices that collected data in unrestrained monkeys. The system operated
without the power limiting and cumbersome restraints exhibited by these previous
systems. For this design, an on board spike processing and a stimulator circuit were
employed to allow for real-time bidirectional interface with the nervous system. After
several modifications, Fetz et al. successfully created a device that was able to
simultaneously record electromyogram (EMG) activity and neural activity at the
implant. The lithium battery operated power source and electronic data systems were
skillfully packaged within a compact percutaneous (inner skin) titanium casing that was
attached to a monkey's skull; the entire implant weighed only 56 g. Neural data was
acquired from 12 microwire electrodes chronically implanted in the primary motor
cortex. Leads run subcutaneously from the head casing to a connector on the monkey's
back. Two pairs of stainless-steel wires were inserted percutaneously into the forearm
muscles where they were attached to an EMG signal recorder (Reference 44).
15
UNCLASSIFIED/,'f81il 8ffl@Itllt ~:!I! 8HLY

Not linked to a story yet.

About this file

Report, from the dia collection. The PDF is mirrored here; the original link is under it. 36 pages are in the text index: search them above, or from the library's search.