This Defense Intelligence Reference Document from the Defense Intelligence Agency, dated 23 March 2010, was produced under the Advanced Aerospace Weapon System Applications (AAWSA) Program. It surveys invasive and noninvasive brain-machine interface technologies for controlling external devices without limb-operated interfaces. The technologies covered include EEG, MEG, fMRI, NIRS, and implanted electrode arrays. It concludes that noninvasive electrical monitoring is the most promising near-term approach. In the long term, it favors invasive single-neuron cortical connections that use optical stimulation or chip-based arrays.

  • p. 5 UNCLASSIFIED/)' Pett :SPPll!ltllt '11815 .,.LY Technological Approaches to Controlling External Devices in the Absence of…
  • p. 8 …Neurons require some time to reset between firings, nominally the duration of the pulse for that…
  • p. 10 UNCLASSIFIED/ ,erg A gffllil.t.L '1181!! 8HLY The brain activity mentioned above is a complex…
  • p. 13 …The response time to execute a command using these systems is measured in seconds. The results…
  • p. 14 …application, the fact that 100 IT is about 100 million times smaller than the Earth's…
  • p. 15 …In current MRis, these gradient fields are produced with electromagnets, and the series of time-dependent…
  • p. 18 …prior to implantation, and then the tasks are repeated multiple times while muscle action and cortical…
  • p. 19 …the movement control algorithm is similar to a population vector in that movement at each time…
  • p. 20 UNCLASSIFIED/,'P81il 8PPll!ltllt ~81!! 8HLV Japan in real time. Using visual feedback to the monkey…
  • p. 21 …employed to allow for real-time bidirectional interface with the nervous system. After several modifications, Fetz…
  • p. 22 …understand the brain, its regions of activity and how those area correlate to real time stimulation…
  • p. 25 …FOV=60x60mrn 7 • Experiment time=512 s. (B) (Top) Microelectrode array used in the study. (Bottom…
  • p. 28 …Movement times to target were on the order of 1-2 seconds with up to 75…
  • p. 29 …This trial lasted 3 months before the physical connection between the nerve and the microarray deteriorated…
  • p. 31 …Also beneficial to reaction time is the combined EMG EEG devices mentioned above since the pathways…
  • p. 32 …Proof of principle studies in this technology could emerge at any time, and given the demonstrated…
  • p. 34 …time. J Cogn Neurosci 2002 Nov 15; 14(8): 1200-14. " Hatsopoulos NG, Donoghue JP. The…
  • p. 36 …Targeted muscle reinnervation for real- time myoelectric control of multifunction artificial arms. JAMA 2009 Feb 11…
UNCLASSIFIED/ ,SF&lil: 8FFI1il.t.k Wfili &,.kY
An issue develops when an entirely new device is considered. The form of the
movement control algorithm is similar to a population vector in that movement at each
time step is determined by a vector sum of the neurons' normalized firing rates
multiplied by a set of linear coefficients. Modern neuroscience has proven that tens of
thousands, even up to millions of neurons fire in concert to perform even the most
mundane of movements. These extended neural pathways developed through full-
duplex closed loop training. It will thus be quite an issue in an open-loop design to
develop an algorithm that can decode control signals for a system the brain has never
controlled before, say a 12-direction rocket stabilization system. 17 This places another
limitation on the open-loop model, even using complex nonlinear fitting, and has driven
development of the closed-loop model.
CLOSED-LOOP PERIPHERAL ARRAYS UTILIZING VISUAL FEEDBACK
In a closed-loop system that provides feedback to a control system, the differences
between the two models of movement become apparent. Sensory feedback within the
system is used for error correction of fine motor control, such as balance - without fine
motor control and error correction for balance, the human body could not stand up. In
the model with abstract cortical control, feedback corrections are processed externally
to the BMI and sensory feedback to the brain is usually limited to observation. This is a
subtle distinction between open-loop with visual feedback and closed-loop abstract
control that includes visual feedback. In the former, the visual feedback is intended to
show success of a control command being sent by the brain, whereas in the latter,
visual feedback is showing success of supervisory function of a semiautonomous
mechanical device.
Figure 4. Experimental Overview of Brain-Controlled Robot in a Closed-Loop With Visual Feedback
Experiment. After decoding walking-related information from a monkey's brain activity while walking on a
treadmill, these data were relayed from Duke University in USA to the Advanced Telecommunication Research in
17 Twelve directions are the minimum number of positive controls commands to+/- x, y, and z thrust, as well as
increasing or decreasing roll, pitch, and yaw. These are six degrees of freedom but as far as a BMI control system
is concerned, increasing x and decreasing x are separate commands to decode.
13
UNCLASSIFIED/ ,<EiOA. QEiFiliIAk ~:!II!! 8HL I

Not linked to a story yet.

About this file

Report, from the dia collection. The PDF is mirrored here; the original link is under it. 36 pages are in the text index: search them above, or from the library's search.