This Defense Intelligence Reference Document from the Defense Intelligence Agency, dated 23 March 2010, was produced under the Advanced Aerospace Weapon System Applications (AAWSA) Program. It surveys invasive and noninvasive brain-machine interface technologies for controlling external devices without limb-operated interfaces. The technologies covered include EEG, MEG, fMRI, NIRS, and implanted electrode arrays. It concludes that noninvasive electrical monitoring is the most promising near-term approach. In the long term, it favors invasive single-neuron cortical connections that use optical stimulation or chip-based arrays.

  • p. 5 UNCLASSIFIED/)' Pett :SPPll!ltllt '11815 .,.LY Technological Approaches to Controlling External Devices in the Absence of…
  • p. 8 …Neurons require some time to reset between firings, nominally the duration of the pulse for that…
  • p. 10 UNCLASSIFIED/ ,erg A gffllil.t.L '1181!! 8HLY The brain activity mentioned above is a complex…
  • p. 13 …The response time to execute a command using these systems is measured in seconds. The results…
  • p. 14 …application, the fact that 100 IT is about 100 million times smaller than the Earth's…
  • p. 15 …In current MRis, these gradient fields are produced with electromagnets, and the series of time-dependent…
  • p. 18 …prior to implantation, and then the tasks are repeated multiple times while muscle action and cortical…
  • p. 19 …the movement control algorithm is similar to a population vector in that movement at each time…
  • p. 20 UNCLASSIFIED/,'P81il 8PPll!ltllt ~81!! 8HLV Japan in real time. Using visual feedback to the monkey…
  • p. 21 …employed to allow for real-time bidirectional interface with the nervous system. After several modifications, Fetz…
  • p. 22 …understand the brain, its regions of activity and how those area correlate to real time stimulation…
  • p. 25 …FOV=60x60mrn 7 • Experiment time=512 s. (B) (Top) Microelectrode array used in the study. (Bottom…
  • p. 28 …Movement times to target were on the order of 1-2 seconds with up to 75…
  • p. 29 …This trial lasted 3 months before the physical connection between the nerve and the microarray deteriorated…
  • p. 31 …Also beneficial to reaction time is the combined EMG EEG devices mentioned above since the pathways…
  • p. 32 …Proof of principle studies in this technology could emerge at any time, and given the demonstrated…
  • p. 34 …time. J Cogn Neurosci 2002 Nov 15; 14(8): 1200-14. " Hatsopoulos NG, Donoghue JP. The…
  • p. 36 …Targeted muscle reinnervation for real- time myoelectric control of multifunction artificial arms. JAMA 2009 Feb 11…
UNCLASSIFIED/ ,'FOR OFFIGII k WEE a••k>/
EMG
Instead of measuring nerve impulses and amplifying them, one can design a system
that monitors muscle movement in a hands-free approach to a mechanical interface,
essentially using the muscles as a biological amplifier of neural signals. One may close
the feedback loop using a heads-up display, monocle, or other visual device, or another
traditional sensory feedback. The advantage of such a design is that controls may be
actuated through a lightweight wireless system, effectively providing control stations
anywhere such a wireless system would work. Such a system could be used to untie a
pilot from the cockpit. Recent work has shown that performance of 1-2 bits/s is possible
with minimal training, about four times the current performance of a comparison EEG
forehead sensor (Reference 14).
MRI AND FMRI
Magnetic Resonance Imaging (MRI) works by a simple excitation and relaxation of spin
states. When molecules containing hydrogen are placed in a strong static magnetic
field, a small but detectable number of hydrogen protons align their intrinsic spins along
the direction of the external field. An applied radiofrequency (RF) pulse near the proton
resonant frequency, 42.6 MHz/Tesla or 128 MHz at 3 Tesla, knocks the spins
perpendicular to the field and the relaxation back to ground state releases RF energy in
patterns that can be reconstructed to show both composition and distribution of any
hydrogen-rich materiel. The resonant frequency is a direct function of the local
magnetic field defined by the Larmor relation: (1) = y B; where rn is the frequency of
precession, B is the local magnetic field, and y is a constant of the material, 42.6
MHz/Tesla for bare protons as mentioned above.
Small perturbations to the static field will change the resonant frequency. By applying a
small gradient to the static field, for example 100 milliTesla/meter along the z-axis, and
limiting the bandwidth of the RF excitation signal to Orn, one may select a slice of the
brain perpendicular to the z-axis for excitation to Oz. A change in the gradient field will
change the position of the excited slice for the next excitation. Similar gradients in the
x and y directions can limit the excitation to a single small volume of brain tissue. In
current MRis, these gradient fields are produced with electromagnets, and the series of
time-dependent imaging gradient manipulations is called the scan sequence.
Free hydrogen (H) would produce a resonant signal slightly different than the bare
proton due to the local field changes induced by its valance electron. Hydrogen gas (H2)
would produce a still different frequency since the local field around each proton is
altered by the two shared electrons. Water molecules (H2O) contain two hydrogen
atoms and an entirely different "electron shield" than either H or H2 and thus shows still
another slightly different resonant frequency. Fat and other lipid molecules, important
cell structure building blocks, have long chains of hydrocarbons, and the resulting
ensemble of electron screening produces a wide peak that is substantially shifted 10
from that of water.
Brain gray matter and white matter have different macroscopic lipid content and are
thus able to be differentiated in an MRI scan. Different signals also arise in bone,
1° Frequency detection sensitivities in MRI are very good, and "substantial" here means about 3 parts per million.
The frequency shifts caused by ,maging gradients ranges ,n the parts per thousand.
9
UNCLASSIFIED/ ,,roPt OFFIGilk IP&'i Ollk¥

Not linked to a story yet.