Documents / Report

Defense Intelligence Reference Document Technological Approaches To Controlling

Defense Intelligence Agency · 36 pages · text from the file's own layer

This Defense Intelligence Reference Document from the Defense Intelligence Agency, dated 23 March 2010, was produced under the Advanced Aerospace Weapon System Applications (AAWSA) Program. It surveys invasive and noninvasive brain-machine interface technologies for controlling external devices without limb-operated interfaces. The technologies covered include EEG, MEG, fMRI, NIRS, and implanted electrode arrays. It concludes that noninvasive electrical monitoring is the most promising near-term approach. In the long term, it favors invasive single-neuron cortical connections that use optical stimulation or chip-based arrays.

  • p. 5 UNCLASSIFIED/)' Pett :SPPll!ltllt '11815 .,.LY Technological Approaches to Controlling External Devices in the Absence of…
  • p. 8 …Neurons require some time to reset between firings, nominally the duration of the pulse for that…
  • p. 10 UNCLASSIFIED/ ,erg A gffllil.t.L '1181!! 8HLY The brain activity mentioned above is a complex…
  • p. 13 …The response time to execute a command using these systems is measured in seconds. The results…
  • p. 14 …application, the fact that 100 IT is about 100 million times smaller than the Earth's…
  • p. 15 …In current MRis, these gradient fields are produced with electromagnets, and the series of time-dependent…
  • p. 18 …prior to implantation, and then the tasks are repeated multiple times while muscle action and cortical…
  • p. 19 …the movement control algorithm is similar to a population vector in that movement at each time…
  • p. 20 UNCLASSIFIED/,'P81il 8PPll!ltllt ~81!! 8HLV Japan in real time. Using visual feedback to the monkey…
  • p. 21 …employed to allow for real-time bidirectional interface with the nervous system. After several modifications, Fetz…
  • p. 22 …understand the brain, its regions of activity and how those area correlate to real time stimulation…
  • p. 25 …FOV=60x60mrn 7 • Experiment time=512 s. (B) (Top) Microelectrode array used in the study. (Bottom…
  • p. 28 …Movement times to target were on the order of 1-2 seconds with up to 75…
  • p. 29 …This trial lasted 3 months before the physical connection between the nerve and the microarray deteriorated…
  • p. 31 …Also beneficial to reaction time is the combined EMG EEG devices mentioned above since the pathways…
  • p. 32 …Proof of principle studies in this technology could emerge at any time, and given the demonstrated…
  • p. 34 …time. J Cogn Neurosci 2002 Nov 15; 14(8): 1200-14. " Hatsopoulos NG, Donoghue JP. The…
  • p. 36 …Targeted muscle reinnervation for real- time myoelectric control of multifunction artificial arms. JAMA 2009 Feb 11…
UNCLASSIFIED/;«F&A 8FFHil.l1k WE&i a••k>/
second transferred. Higher bit rates equate to more efficient interfaces. Baseline
examples of performance include finger pointing, which can convey 14 bits/s of
information (Reference 13), operation of a mouse about 8 bits/s (Reference 14), while
stylus tapping a soft QWERTY keyboard on a PDA has a lower rate, around 5 bits/s
(Reference 15).
Once these questions are researched and answered for a given application, the design
choice should be made whether a new mechanical interface, or an optical interface that
tracking detailed motion of the eyes, body and limbs, may be the optimum solution
rather than a BMI. 5
Another consideration in developing a BMI control system is the cognitive limit of
supervisory control of external devices. The current state of the art for human
interfaces involves volition of control, meaning that there is some executive
supervision, typically involving the pre-frontal cortex, active during the control process.
Recent studies relating to control of semiautonomous vehicles show that there are
significant limits on the number of supervisory activities that can be undertaken
simultaneously (Reference 16). In response to these limits, one can consider utilization
of nonsupervised brain networks in control of external devices, similar to those brain
systems that initiate very complex muscle coordination activity such as martial arts or
playing a musical instrument, or systems like those that are responsible for autonomic
function. Application from such research is long term, but there are current studies that
show BMI training of at least one spinal cord patient exhibited differential activity in the
cerebellum, owing to extraordinary plasticity (Reference 17). It is therefore not out of
the realm of possibility that sufficient input and output interfaces that include neural
pathways through the cerebellum could result in over-learning a BMI application to the
point that supervisory control is developed and thus significant cognitive effort is not
required.
Noninvasive Technologies
There are four noninvasive technologies currently in widespread use in monitoring brain
activity. The two direct-measure technologies involve detecting surface currents from
the relative voltage changes at or just below the scalp, electroencephalography (EEG),
and detection of near scalp magnetic fields associated with neural pathway current flow,
magnetoencephalography (MEG). The remaining two indirect measures involve
monitoring BOLD response through rapid successions of whole brain MRI (functional
MRI or fMRI), and near-infrared spectroscopy (NIRS). 6
The primary technology used for BMI is also the oldest. EEG was first described in 1929
(Reference 18) and now exists in several derivative forms. Traditional EEG uses
electrodes at the surface of the scalp to measure and amplify potential differences
between points above the cortical surface and a fixed reference such as the average
reading from the earlobes. Traditional EEG data is analyzed by breaking up the power
spectrum into several bands between 0.5 and 100 Hz. A derivative form of EEG
developed about 10 years later is called event-related potentials, or ERP. In ERP, scalp
s There is a valid argument to be made that optical tracking and analysis, especially of the eyes, is a BM!
technology as defined in the current treatise. It 1s excluded as one merely by fiat.
6 NIRS 1s occasionally referred to as functional NIRS or fNIRS. NIRS using multiple sources to produce 3D images of
internal changes in blood flow is occasionally ca11ed diffuse optical tomography (DOT). OOT is a more general
technology that can also refer methods such as to visible-light laser excitation of tissue.
6
UNCLASSIFIED/,'P9Pl err1e1111t ~:!I! 9HLY

Not linked to a story yet.

About this file

Report, from the dia collection. The PDF is mirrored here; the original link is under it. 36 pages are in the text index: search them above, or from the library's search.