Documents / Report

Defense Intelligence Reference Document Technological Approaches To Controlling

Defense Intelligence Agency · 36 pages · text from the file's own layer

This Defense Intelligence Reference Document from the Defense Intelligence Agency, dated 23 March 2010, was produced under the Advanced Aerospace Weapon System Applications (AAWSA) Program. It surveys invasive and noninvasive brain-machine interface technologies for controlling external devices without limb-operated interfaces. The technologies covered include EEG, MEG, fMRI, NIRS, and implanted electrode arrays. It concludes that noninvasive electrical monitoring is the most promising near-term approach. In the long term, it favors invasive single-neuron cortical connections that use optical stimulation or chip-based arrays.

  • p. 5 UNCLASSIFIED/)' Pett :SPPll!ltllt '11815 .,.LY Technological Approaches to Controlling External Devices in the Absence of…
  • p. 8 …Neurons require some time to reset between firings, nominally the duration of the pulse for that…
  • p. 10 UNCLASSIFIED/ ,erg A gffllil.t.L '1181!! 8HLY The brain activity mentioned above is a complex…
  • p. 13 …The response time to execute a command using these systems is measured in seconds. The results…
  • p. 14 …application, the fact that 100 IT is about 100 million times smaller than the Earth's…
  • p. 15 …In current MRis, these gradient fields are produced with electromagnets, and the series of time-dependent…
  • p. 18 …prior to implantation, and then the tasks are repeated multiple times while muscle action and cortical…
  • p. 19 …the movement control algorithm is similar to a population vector in that movement at each time…
  • p. 20 UNCLASSIFIED/,'P81il 8PPll!ltllt ~81!! 8HLV Japan in real time. Using visual feedback to the monkey…
  • p. 21 …employed to allow for real-time bidirectional interface with the nervous system. After several modifications, Fetz…
  • p. 22 …understand the brain, its regions of activity and how those area correlate to real time stimulation…
  • p. 25 …FOV=60x60mrn 7 • Experiment time=512 s. (B) (Top) Microelectrode array used in the study. (Bottom…
  • p. 28 …Movement times to target were on the order of 1-2 seconds with up to 75…
  • p. 29 …This trial lasted 3 months before the physical connection between the nerve and the microarray deteriorated…
  • p. 31 …Also beneficial to reaction time is the combined EMG EEG devices mentioned above since the pathways…
  • p. 32 …Proof of principle studies in this technology could emerge at any time, and given the demonstrated…
  • p. 34 …time. J Cogn Neurosci 2002 Nov 15; 14(8): 1200-14. " Hatsopoulos NG, Donoghue JP. The…
  • p. 36 …Targeted muscle reinnervation for real- time myoelectric control of multifunction artificial arms. JAMA 2009 Feb 11…
UNCLASSIFIED/ ,erg A gffllil.t.L '1181!! 8HLY
The brain activity mentioned above is a complex chain of ionic motion within the central
nervous system. Ionic production, release, and movement within and between cells all
consume energy. This energy is supplied by the conversion of blood-borne
oxyhemoglobin to deoxyhemoglobin. The rate of oxygen consumption in a localized
volume varies based on local neural activity. The circulatory system compensates for
changes in energy demand by increasing or decreasing both the flow rate and volume
of blood, regionally and locally. Local energy demand, expressed in the capillary beds,
will alter the rate at which oxygen is metabolized, called the cerebral rate of oxygen
metabolism, abbreviated CMRO2. When brain activity increases in a region, the
circulatory response, called the hemodynamic response, will be increases in flow and
volume, while the local areas increase CMRO2.
The hemodynamic response consistently provides an excess of oxygen over what is
required, and this results in some oxyhemoglobin traveling through the capillary bed
and local venous structure without being converted into deoxyhemoglobin. Oxy- and
deoxyhemoglobin have different magnetic susceptibilities, and different infrared
spectra. The hemodynamic response, by changing the net ratio of oxy- to
deoxyhemoglobin in the local venous structure, thus changes the local magnetic
susceptibility and local infrared resonance spectra around focused brain activity. This
complex chain reaction is called the Blood Oxygen Level Dependent, or BOLD effect
(Reference 8). The BOLD effect leads to a method to indirectly measure the local brain
activity by monitoring the hemodynamic response using Magnetic Resonance Imaging
(MRI) or Near Infrared Spectroscopy (NIRS).
The BOLD response to any event peaks about 4-6 seconds a~er the event occurs,
limiting the applications for which monitoring these signals and their associated delay
may be useful, given the BMI operating parameters defined above Furthermore, person
to person variation in distributed signals show significant differences in regions
activated (Reference 9), though there is evidence that these inter-subject variations are
stable intra-subject over time (Reference 10).
Control of External Devices
In general, there are two types of BMI design called open-loop and closed-loop. Open
loop designs, those either detecting activity or providing stimulation, are important for
BMI research and application other than the practical control of an external device.
Closed-loop systems include both output signals from the brain to effect a change in the
state of a device, and a stimulation channel, which can be used as feedback. In some
system designs, the feedback can be via visual cues such as watching a display
(Reference 11). Open-loop systems are important for BMI research and have
application in sense replacement such as artificial hearing, or when extensive output
signal processing is combined with external device state feedback (see remote robot
operation below). For learning and fine, efficient control of external devices without
significant external processing, closed-loop systems are typically needed.
Several components constitute a general BMI system for control of an external device
(Figure 2). As mentioned in the previous section, the interfaces where the information
signal makes the jump between biological and physical pathways are the most
challenging part of the system. These connections can be placed to stimulate or read
peripheral or cerebral neurons. The processing step could be as simple as amplification
4
UNCLASSIFIED/;CfgA gccIGIPk IP&'i Ollk¥

Not linked to a story yet.

About this file

Report, from the dia collection. The PDF is mirrored here; the original link is under it. 36 pages are in the text index: search them above, or from the library's search.