This Defense Intelligence Reference Document from the Defense Intelligence Agency, dated 28 January 2010, surveys pulsed high-power microwave (HPM) source technology. It was produced under the Advanced Aerospace Weapon System Applications (AAWSA) program. It covers insulation, cathode materials, high-voltage switching, pulse generators, microwave sources such as magnetrons, gyrotrons and the Phoenix and Jolt sources, and antennas. The document concludes that progress depends on advances in cathodes, switching and insulation. It says compact ultrawideband antennas will remain difficult to build.

  • p. 6 …on the order of several hundreds of kilovolts per meter with onset or rise times of…
  • p. 7 …If the pulse duration is short compared with thermal diffusion times, then the temperature increases in…
  • p. 8 …The short burst mode operation is necessary because of the high peak powers and subsequent heating…
  • p. 17 …Second, it has a fast turn-on time. Third, the insulating nature of the velvet fibers…
  • p. 18 …As a result, the HPM emission times have been extended. Typically, the cesium salt is dissolved…
  • p. 19 …The period of the lowest frequency is twice the pulse width, and the rise time is…
  • p. 20 …Thus, the faster the rise time and the wider the pulse, the broader the spectral content…
  • p. 21 …8FF11il.t.k WE&i a••k>/ rise time is the time required to heat the…
  • p. 22 …The array can then be phased in time to allow steering of the beam. GaAs switches…
  • p. 24 …The explosives are then used to compress the initial magnetic flux by driving the conducting cylinder…
  • p. 26 …SPLIT-CAVITY OSCILLATORS Split-cavity oscillators (SCOs) utilize transit-time bunching of the beam to generate…
  • p. 28 …in the 3.5-ns-wide pulse is 1.25 GW, and the rise time is…
  • p. 29 …Thus, for H3 the FOM is 250 kV. While developing the H series of HPM sources…
  • p. 30 …Phoenix had the fastest rise time of any HPM source to date. Figure 8 shows the…
  • p. 32 …By timing the switching sequence of each BASS module, the beam was steerable up to 30…
  • p. 35 …Thus, if the frequency chirps during the RF pulse, then the beam direction will sweep. The…
  • p. 36 …This is why the rise time of the driving pulse is so important to antenna response…
UNCLASSIFIED,' fF&II. lilFFll!l*le lel!II!! !IIU:!Y
Figure 2 shows an example of a Marx generator circuit.
"" -,-,- .
------- t i;-,
,.,.,
,.
Figure 2. Example of Marx Generator Circuit
TRANSFORMER BASED GENERATORS
;,·,· ~
'______.. =
"
Transformer-based pulse generators have also been used for many years as prime
power for HPM sources. Transformers with ferrite cores have been used successfully in
sources with multigigawatt output powers at kilohertz repetition rates. Ferrite
development is an area where substantial gains could be made in HPM sources.
Typically, programs are under time or budget constraints and do not give adequate
attention to this research. As a result, little or no progress in new ferrite materials for
pulsed operation has been made. Ferrites with increased frequency ranges and
increased saturation flux density are needed. Air core transformers are used at higher
flux densities and are often of the resonant variety because of their decreased coupling
levels. Resonant transformers develop peak voltages after multiple cycles owing to
coupling effects. Dual-resonant air core pulse transformers are prevalent and require
coupling coefficients of 0.8, producing peak secondary voltage and maximum energy
transfer after an initial reverse voltage swing. In dual-resonant designs, two
frequencies or resonant modes are generated, and the output is the superposition of
the two modes. Transformer systems generally require the primary circuit to be
matched or tuned to the secondary, or vice versa.
EXPLOSIVELY DRIVEN GENERATORS
Explosively driven generators, also called flux compression generators (FCGs), work by
setting up a strong magnetic field between two conductors, usually by discharging a
capacitor bank charged to high voltage through an inductive coil. A conducting hollow
cylinder filled with high explosives is placed in the center of the coil, filling the region
between the two conductors with magnetic flux. The explosives are then used to
compress the initial magnetic flux by driving the conducting cylinder surface, which
contains the flux, outward into the current carrying coil. Work done by the conductors
moving against the magnetic field results in a huge increase in the EM energy. The
additional energy comes from chemical energy stored in the explosives. Thus, FCGs
essentially convert a portion of the chemical explosive energy into EM energy. The
explosively driven conductor is called an armature, and the nondriven inductive coil of
the generator is called the stator. Miniaturizing the generators and fine-tuning the
magnetohydrodynamic aspects takes years and is still an area of intense research.
Material properties under the enormous forces involved are also required for success.
Many hours of research and computer code writing and testing go into the selection of
every single material used. One problem with this form of HPM source is that of
coupling the energy to the load. Attempts to energize the load by direct generation
often result in the development of excessive internal generator voltages and
16