Documents / Report

Defense Intelligence Reference Document Inertial Electrostatic Confinement Fusion

Defense Intelligence Agency · 72 pages · text from the file's own layer

This Defense Intelligence Agency reference document, dated 10 March 2010, covers inertial electrostatic confinement (IEC) fusion. It was produced in FY 2009 under the DIA's Advanced Aerospace Weapon System Applications (AAWSA) program. The report focuses on work at the University of Illinois Urbana-Champaign and reviews IEC basics, experiments, theory and applications such as neutron sources, explosives detection and space propulsion. It concludes by proposing a breakeven experiment for p-11B fusion that uses a hydrogen plasma simulation.

  • p. 8 …This is important for long run times since 10n bombardment of the grids, hence grid wire…
  • p. 9 …This time can be restated in terms of the number of ion recirculations in the IEC…
  • p. 15 …This work and others on the small gridded systems at that time showed several important problems…
  • p. 17 …interesting concept is the idea of ion focusing, either in space or time, or some other…
  • p. 18 …confinement time for aneutronic fusion. This assumes, however, very precise control is maintained over the energy…
  • p. 23 …By selecting the pulse width to match or exceed the ion confinement time, typically order of…
  • p. 27 …This is the approach used at the UIUC. However, introduction of the source into the configuration…
  • p. 30 …The second jet would serve the integration purpose of the platform without having to expend time…
  • p. 35 …The issue then is how to achieve adequate confinement times. The approach being pursued at UIUC…
  • p. 36 …step in a timely fashion, however. The Dipole Assisted IEC (DaIEC) The dipole assisted IEC DaIEC…
  • p. 38 …in the current experiment. It is found that electron density increases about 17 times more than…
  • p. 41 …Namely, the time scale for collisional degradation of the beam-like ion distribution function is crucial…
  • p. 42 …would homogenize the speed within the ion beam a~er some time, making the speed difference…
  • p. 43 …1) The electrostatic well is deep enough (Eo > 100 kV); 2) Ion confinement time is long…
  • p. 44 …The source to sink issue noted several times here can be explained as follows. Two opposite…
  • p. 49 …The time convergence test suggests that employing the largest time step compatible with accuracy in a…
  • p. 50 …When an ion beam is hot, the waves excited by the instability are ion acoustic type…
  • p. 51 …used an analytical model of charge- exchange collisions in the IEC plasma to include ion time…
  • p. 53 …Nevins, Can inertial electrostatic confinement work beyond the ion-ion collisional time scale?" Phys. Plasmas, Vol…
  • p. 54 …This method uses a pulsed high-energy neutron source and the time-of-flight (TOF) diagnostics…
  • p. 57 …The longer the charge time, the higher the charge in the energy storage capacitor bank and…
  • p. 58 …The challenge in these systems is that the unloading time is short and the container is…
  • p. 59 …by the number of detectors, the detector configuration, the collimated beam size, the acquisition time, and…
  • p. 62 …The Tokamak has a shorter trip time by employing a power level that is six times…
  • p. 63 …In this fashion, an array of multiple IECs increase the overall confinement time roughly in proportion…
  • p. 64 …This recirculation significantly increases the confinement time verses that of a simple cusp devise, leading to…
  • p. 65 …This re-trapping greatly increases the confinement time of a MCSA fusion device. 58 UNCLASSIFIED/;CEiOAt…
  • p. 66 …in the IEC high power-to-weight of the MCSA enables fast trip times. The concept…
  • p. 67 …across the outer surface, so increased confinement times have been achieved by going to the massively…
  • p. 68 …Here n is the ion density and Tis the ion confinement time. Assuming the converged core…
  • p. 69 …A specially designed radio frequency (RF) ion gun is installed on the side of the chamber…
UNCLASSIFIED/ /F81il 8FFI1il.t.k Wfili 8Hklf
Retrapping of Axial-Loss Particles
Axial plasma particle loss escaping out through the end cone (spindle cone) of the first
MCSA unit should be retrapped in the second unit because of "KAM effective
scattering". This KAM scattering occurs as particles move into the null-field region
within each SIEC unit. Figure 5.9 illustrates the axial magnetic field component along
the centerline of a two-unit MCSA. Particles escaping from the low field region of one
unit pass into the neighboring unit through the high magnetic field region between the
two-units. Upon entering the IEC region, the direction of the particle is effectively
randomized (i.e. Kam Scatter) when it loses adiabatic invariance in the field null region.
Although particles with high velocities parallel to the magnetic field will not experience
as much effective scattering, a majority of the particles entering the null field region
should experience scattering and retrapping.
120
100
80
60
40
20
0
Low-Field
Confinemen
Re-!!1011;:,
\\,,
High-F,,Id
-20-~J___~-0~.~5___~0___~0~.5~--
Axial Position (m)
Figure 5.9. Axial Magnetic Field Strength Along Two-Unit MCSA Centerline
1
This KAM scattering process is illustrated conceptually in Figure 5.10. Before entering
the null-field region, particles have a gyroradius that depends on their perpendicular
velocity. If vis large compared to v11, the effective scattering angle will be large,
resulting in retrapping in the case of the MCSA. In the high-field region, the gyro-radius
of the particle is small. When the low-field region is reached, the particle moves in a
straight-line path along the vector direction at the edge of the null region. Since the
phase of the gyro motion of the particles is random at this point, the vector direction
they assume in crossing the null is random. The result then can be viewed, as a
random, collisionless, scattering process. Particles that stream along the axis and enter
a neighboring IEC scatter in this way and become confined in the neighboring IEC
(termed axial-loss "re-trapping"). This re-trapping greatly increases the confinement
time of a MCSA fusion device.
58