Documents / Report

Defense Intelligence Reference Document Inertial Electrostatic Confinement Fusion

Defense Intelligence Agency · 72 pages · text from the file's own layer

This Defense Intelligence Agency reference document, dated 10 March 2010, covers inertial electrostatic confinement (IEC) fusion. It was produced in FY 2009 under the DIA's Advanced Aerospace Weapon System Applications (AAWSA) program. The report focuses on work at the University of Illinois Urbana-Champaign and reviews IEC basics, experiments, theory and applications such as neutron sources, explosives detection and space propulsion. It concludes by proposing a breakeven experiment for p-11B fusion that uses a hydrogen plasma simulation.

  • p. 5 …Photo of Center Spot Formation ......................................................... 12 Figure 2.1. The "Historic" Early IEC Ion Injection Experiment…
  • p. 9 …The ideal, however, is the elimination of the grid altogether which can be done via formation…
  • p. 12 …This result was quite negative for electron formation of potential wells, but left the route possibly…
  • p. 14 …most critical factors which inhibit deep well formation are inadequate spherical focusing and charge neutralization. The…
  • p. 18 …The ion formation is done in the high pressure gun discharge region outside of the chamber…
  • p. 19 …Photo of Center Spot Formation. The main beam observed is a direct path along the injector…
  • p. 20 …Klevans, "Theory of Potential-Well Formation in an Electrostatic Confinement Device", J. of Appl. Phys., Vol…
  • p. 22 …As shown in the paper, he found structure for both consistent with well formation. One possible…
  • p. 30 …However, to date, formation of the jet has only been studied under steady-state operation. 23…
  • p. 31 …The result is the formation of the intense space charge neutralized ion beam (or "plasma jet…
  • p. 32 …This type of ion formation in the IEC has been studied extensively by workers at Nambe…
  • p. 35 …The approach being pursued at UIUC is the formation of deep potential wells with angular ion…
  • p. 45 …considered well formation with emphasis on angular momentum effects (Reference 4.4). Earlier studies had assumed…
  • p. 48 …is very encouraging for formation of deep wells in IEC devices designed for reactors using beam…
  • p. 49 …Krylov algorithm that does not require actual formation and storage of the Jacobian matrix to minimize…
  • p. 69 …While very demanding, plasma simulations show that carefully controlled injection can provide the potential well formation…
  • p. 70 …This eliminates the need for a grid by formation of a deep potential well (ion trap…
UNCLASSIFIED/ ,'1"1!11'- l!ll"l"ll!lllile lal!i! 8Hlo'f
bank discharges. The pulse shaper is a tapped inductive line with each tap terminated
by a pulse-forming network (PFN). Each tap performs a filtering function for a discrete
Fourier function or band of frequencies, which results in a smoother, and more uniform
pulse rise and fall, and also provides more constant load impedance matching, as the
IEC tube has high input impedance. This aids in the forward coupling of energy into the
IEC by minimizing backward or reflected standing waves generated by the dynamic
impedance discontinuity presented by the spark gap and the cathode to anode circuit
path. The PFN, in effect, serves as a pulsed coupled transformer with a low input
impedance and a high output impedance to drive the IEC tube. Components for the PFN
are off-the-shelf and commercially available. The spark gap trigger is activated by an
IGBT (isolated fate bipolar transistor) driven by the power control circuits.
A stable multivibrator timer circuit is reset each time the spark gap is fired by a fast
phototransistor circuit that detects spark-generated photons. This is coupled by a light
wave-guide or optical fiber to provide high voltage isolation between the solid-state
control circuits and the high voltage sections. This optically isolated signal is input to
signal processing to give time of flight measurements. A digital or manual
potentiometer range selector controls the time delay by increasing or decreasing the
resistance in an RC network. When the capacitor in this network charges to a nominal
voltage threshold, the timer circuit changes its logic state and drives the gate of the
spark gap trigger IGBT on, and this initiates the spark gap arc. This RC time period
ramp is an analog of the energy storage capacitor charging ramp, which also begins
after the main arc occurs and drains the energy store. The longer the charge time, the
higher the charge in the energy storage capacitor bank and the higher the voltage is
when the next pulse is initiated. The voltage applied to the IEC tube is thus varied over
a nominal 40 percent range. The peak output voltage can therefore be varied over a
range of SO kV to 120kV. There is a reciprocal relationship between the pulse repetition
frequency and the output pulse peak power.
Design of the Total Integrated Interrogation System
The integrated system is illustrated conceptually in Figure 5.2.
so UNCLASSIFIED/ /F81it 8FFIIIAI!: 1!181! &••1::Y

Not linked to a story yet.

About this file

Report, from the dia collection. The PDF is mirrored here; the original link is under it. 72 pages are in the text index: search them above, or from the library's search.