Documents / Report

Defense Intelligence Reference Document Inertial Electrostatic Confinement Fusion

Defense Intelligence Agency · 72 pages · text from the file's own layer

This Defense Intelligence Agency reference document, dated 10 March 2010, covers inertial electrostatic confinement (IEC) fusion. It was produced in FY 2009 under the DIA's Advanced Aerospace Weapon System Applications (AAWSA) program. The report focuses on work at the University of Illinois Urbana-Champaign and reviews IEC basics, experiments, theory and applications such as neutron sources, explosives detection and space propulsion. It concludes by proposing a breakeven experiment for p-11B fusion that uses a hydrogen plasma simulation.

  • p. 8 …hence a good probability of fusing before being lost from the fusion reaction chamber. In the…
  • p. 11 …If it can, the device would be simpler and smaller than a Tokamak, making it an…
  • p. 14 …However, they showed that grid deformation could be very harmful. This deserves several comments. First, the…
  • p. 15 …Again, this issue will be addressed further later. While earlier workers sought small grid openings designed…
  • p. 17 …More insights will be provided throughout this report, but the reader is encouraged to study the…
  • p. 19 …Upscattering out of the well must be minimized while electron 12 UNCLASSIFIED//EOAt OFFIQI.«1k 11181…
  • p. 29 …It operates by convergence of ions created between the grid and wall onto a small volume…
  • p. 30 …Such thrusters, however, do not scale well to lower powers for small satellites, nor are exhaust…
  • p. 33 …first, the channel grid will be separately hinged with a small servo motor such that its…
  • p. 35 …Thus, the mass of the IEC jet thruster system can potentially be reduced compared to a…
  • p. 43 …More insight into this can be obtained from the distribution functions for trapped ions, sketched in…
  • p. 44 …The source to sink issue noted several times here can be explained as follows. Two opposite…
  • p. 47 …However, since the fusion core radius in these calculations is very small on the order of…
  • p. 49 …instability in finite spherical systems may be excited for small beam velocities compared to those of…
  • p. 50 …However, an experimental study should be performed to verify this result. RIDER - ENERGY BALANCE STUDY Todd…
  • p. 53 …In addition, since both D-D and D- 3He reactions can be used for proton production…
  • p. 54 …This can be viewed as a small scale soft source for individual laboratory studies such as…
  • p. 55 …The 14.1-MeV neutrons from the D-T reaction will be the primary source for…
  • p. 59 …Due to their small size, they can be used in a large array along with TOF…
  • p. 65 …If vis large compared to v11, the effective scattering angle will be large, resulting in retrapping…
  • p. 67 …Fortunately, the IEC can be scaled up in energy gain while keeping a small size since…
  • p. 68 …The small size of the IEC is a key characteristic. If rapid development is to be…
  • p. 71 …In other words, this could also be thought of as a Q=100 DT equivalent breakeven…
UNCLASSIFIED/ /P9R: 9PPl!ltllt t!l91!! 9HL'I'
rays which can be extracted through a special port (requires a thin low-Z window for
transmission). This can be viewed as a small scale soft source for individual laboratory
studies such as done at various large scale national laboratories like ANL, BNL, and LBL
(synchrotron "light sources"). However, this use has not progressed much past the
initial laboratory studies.
The cylindrical geometry offers a unique configuration for security inspection
applications. To illustrate this we next consider a design proposed for such a system.
INTEGRATED X-RAY /NEUTRON SOURCES
This integrated inspection system was proposed by G. Miley, et al., in Reference 5.1. It
incorporates combined 2.5- and 14-MeV IEC neutron sources and an IEC x-ray source.
Such neutron sources have already been described, but some comments about the x-
ray version are worthwhile. The cylindrical IEC, like the spherical one, can be converted
to an attractive tunable x-ray source with minimum alteration of the apparatus. X-ray
operation involves reversing electrode polarities and adding electron emitters along the
vessel wall. Hydrogen gas is substituted for deuterium since in this configuration the
main function of gas ions is to provide electron Bremsstrahlung emission. Intense
emission is concentrated in a small volume surrounding the central axis due to the high
electron density formed there. The resulting x-ray energy spectrum is peaked at an
energy equivalent to about two-thirds of the applied voltage. In the inspection station,
a voltage around 120 kV is employed to obtain ~SO-kV x-rays with some distribution of
energies above and below this mean value. X-ray production is spread along the axis
over a long line-like region in the IEC providing broad area coverage for imaging,
consistent with the broad coverage of the companion IEC neutron sources.
Consequently, the basic concept of the integrated inspection unit is to combine IEC
neutron and x-ray sources plus appropriate detectors into a single "package". This
combination expands the range of elements that can be detected during a single scan
and incorporates x-ray imaging with the 3-D detector array for NAA to obtain improved
identification of the shape and location of suspected objects in a container. In cases
where the object is too large to allow good x-ray penetration, information is still
obtained from the 3-D NAA detector array.
Nuclear and Chemical Explosive Detection Techniques
Most current inspection systems concentrate on x-ray imaging. This interrogation relies
on the photoelectric effect or Compton Scattering Imaging (CSI). It provides good
localization and some geometric information for higher Z materials. The NAA technique,
including both thermal neutron analysis (TNA) and fast neutron analysis (FNA), are
powerful methods for detecting certain types of explosives. Basic elements such as
oxygen, carbon, and chlorine present in the explosives can be identified through the (n,
n'y) reaction initiated by fast neutrons. The gamma rays produced in the reaction are
characteristic of elements being interrogated. Another basic element in many
explosives, nitrogen, is usually measured through (n, y) reactions initiated by thermal
neutrons. Either steady-state or pulsed sources can be employed for TNA. However,
increased sensitivity can be obtained with pulsed FNA (PFNA). This method uses a
pulsed high-energy neutron source and the time-of-flight (TOF) diagnostics to reduce
the "noise" effect resulting from scattered neutrons and x-rays.
47
UNCLASSIFIED/ }EiOAt OEiEiIGIPL IP&'i Ollb¥

Not linked to a story yet.

About this file

Report, from the dia collection. The PDF is mirrored here; the original link is under it. 72 pages are in the text index: search them above, or from the library's search.