Documents / Report

Defense Intelligence Reference Document Inertial Electrostatic Confinement Fusion

Defense Intelligence Agency · 72 pages · text from the file's own layer

This Defense Intelligence Agency reference document, dated 10 March 2010, covers inertial electrostatic confinement (IEC) fusion. It was produced in FY 2009 under the DIA's Advanced Aerospace Weapon System Applications (AAWSA) program. The report focuses on work at the University of Illinois Urbana-Champaign and reviews IEC basics, experiments, theory and applications such as neutron sources, explosives detection and space propulsion. It concludes by proposing a breakeven experiment for p-11B fusion that uses a hydrogen plasma simulation.

  • p. 8 …This is important for long run times since 10n bombardment of the grids, hence grid wire…
  • p. 9 …This time can be restated in terms of the number of ion recirculations in the IEC…
  • p. 15 …This work and others on the small gridded systems at that time showed several important problems…
  • p. 17 …interesting concept is the idea of ion focusing, either in space or time, or some other…
  • p. 18 …confinement time for aneutronic fusion. This assumes, however, very precise control is maintained over the energy…
  • p. 23 …By selecting the pulse width to match or exceed the ion confinement time, typically order of…
  • p. 27 …This is the approach used at the UIUC. However, introduction of the source into the configuration…
  • p. 30 …The second jet would serve the integration purpose of the platform without having to expend time…
  • p. 35 …The issue then is how to achieve adequate confinement times. The approach being pursued at UIUC…
  • p. 36 …step in a timely fashion, however. The Dipole Assisted IEC (DaIEC) The dipole assisted IEC DaIEC…
  • p. 38 …in the current experiment. It is found that electron density increases about 17 times more than…
  • p. 41 …Namely, the time scale for collisional degradation of the beam-like ion distribution function is crucial…
  • p. 42 …would homogenize the speed within the ion beam a~er some time, making the speed difference…
  • p. 43 …1) The electrostatic well is deep enough (Eo > 100 kV); 2) Ion confinement time is long…
  • p. 44 …The source to sink issue noted several times here can be explained as follows. Two opposite…
  • p. 49 …The time convergence test suggests that employing the largest time step compatible with accuracy in a…
  • p. 50 …When an ion beam is hot, the waves excited by the instability are ion acoustic type…
  • p. 51 …used an analytical model of charge- exchange collisions in the IEC plasma to include ion time…
  • p. 53 …Nevins, Can inertial electrostatic confinement work beyond the ion-ion collisional time scale?" Phys. Plasmas, Vol…
  • p. 54 …This method uses a pulsed high-energy neutron source and the time-of-flight (TOF) diagnostics…
  • p. 57 …The longer the charge time, the higher the charge in the energy storage capacitor bank and…
  • p. 58 …The challenge in these systems is that the unloading time is short and the container is…
  • p. 59 …by the number of detectors, the detector configuration, the collimated beam size, the acquisition time, and…
  • p. 62 …The Tokamak has a shorter trip time by employing a power level that is six times…
  • p. 63 …In this fashion, an array of multiple IECs increase the overall confinement time roughly in proportion…
  • p. 64 …This recirculation significantly increases the confinement time verses that of a simple cusp devise, leading to…
  • p. 65 …This re-trapping greatly increases the confinement time of a MCSA fusion device. 58 UNCLASSIFIED/;CEiOAt…
  • p. 66 …in the IEC high power-to-weight of the MCSA enables fast trip times. The concept…
  • p. 67 …across the outer surface, so increased confinement times have been achieved by going to the massively…
  • p. 68 …Here n is the ion density and Tis the ion confinement time. Assuming the converged core…
  • p. 69 …A specially designed radio frequency (RF) ion gun is installed on the side of the chamber…
UNCLASSIFIED,' ff811. 8FFll!l*le lall!! 8111!¥
gridded IECs. Further, the model provides more insight into operation in the STAR
mode. This effect, described earlier in Section 1, is summarized in Figure 4.11.
For higher pressure operation, charge exchange severally limits the number of passes
possible through the grid despite the very high effective transparency achieved by the
STAR mode. This is emphasized by results for the calculations in Reference 4. 7 shown
in Figure 4.12. (Note that related calculations by J. Khachan discussed earlier in Section
II show similar results, but emphasize the role of molecular ions at lower operating
voltages).
Figure 4.11. Diagram Showing Equipotential
Surfaces of the IEC Cathode Grid and Their
Focusing Effect on a Beam of Ions in the star
Mode Discharge at High Voltages(> 50 keV)
Ion Energy Distributions 1st paH
2 cm grid radius, &O kV, 4.8 mTorr
2 .OE+07 ,--------:-c----i
• 1.5E+07
•.2 1 OE:+07 t- --=~
- 5.0E-+00
O.OE+OO
0 20000 """"
ton Energy leVI
1--= lwf ....-Cnll-il
'1--- ...... •c...,.. 'I
--- ..... ~ C.r'4
~ I
Figure 4.12. Results for Calculations for Ion Energy
Distributions is• Pass
These computational results are for the UIUC IEC "A-device" using a diameter grid with
conditions of 50 kV, 10 mA, and 4-cm, and background gas pressure of 4.6 mTorr. At
this pressure, charge-exchange (CX) collisions occur quite frequently for D+ ions. In
their first pass through the IEC, about half of these ions CX within the cathode region
and are lost. After only four passes, most of the remaining ions have lost a large
amount of their original potential energy and the fusion rate from subsequent passes
becomes negligible. D2+ ions have a smaller CX cross section and it takes about 20
passes for most of the D2+ ions to lose their energy and be lost to the grid. (D2+ ions
and also D3+ ions are naturally produced at diminishing quantities in ionization reactions
along with o+. As pointed out by Khachan his work noted D2+ becomes more significant
in lower voltages).
In summary, the design of an optimal IEC neutron source is seen to be quite different
from a power-producing IEC. In the source design, the grid parameters, grid/vessel
diameter ratio, chamber diameter, surface conditions, background pressure, current,
and voltage all become important parameters. In power-producing devices the ion
injection parameters-- including ion current, ion energy relative to height of the well
potential, the ion angular momentum, and the ion to electron temperature ratio, along
with the chamber diameter ---determine performance. The calculations and simulations
cited here provide much insight into these issues and also provide insight into
theoretical and computational tools for IEC study.
45
UNCLASSIFIED/ ;«F81it 8FFIIIAI!: 1!181! &••1::Y

Not linked to a story yet.