Defense Intelligence Reference Document Inertial Electrostatic Confinement Fusion

Defense Intelligence Agency · 72 pages · text from the file's own layer

This Defense Intelligence Agency reference document, dated 10 March 2010, covers inertial electrostatic confinement (IEC) fusion. It was produced in FY 2009 under the DIA's Advanced Aerospace Weapon System Applications (AAWSA) program. The report focuses on work at the University of Illinois Urbana-Champaign and reviews IEC basics, experiments, theory and applications such as neutron sources, explosives detection and space propulsion. It concludes by proposing a breakeven experiment for p-11B fusion that uses a hydrogen plasma simulation.

  • p. 8 …hence a good probability of fusing before being lost from the fusion reaction chamber. In the…
  • p. 11 …If it can, the device would be simpler and smaller than a Tokamak, making it an…
  • p. 14 …However, they showed that grid deformation could be very harmful. This deserves several comments. First, the…
  • p. 15 …Again, this issue will be addressed further later. While earlier workers sought small grid openings designed…
  • p. 17 …More insights will be provided throughout this report, but the reader is encouraged to study the…
  • p. 19 …Upscattering out of the well must be minimized while electron 12 UNCLASSIFIED//EOAt OFFIQI.«1k 11181…
  • p. 29 …It operates by convergence of ions created between the grid and wall onto a small volume…
  • p. 30 …Such thrusters, however, do not scale well to lower powers for small satellites, nor are exhaust…
  • p. 33 …first, the channel grid will be separately hinged with a small servo motor such that its…
  • p. 35 …Thus, the mass of the IEC jet thruster system can potentially be reduced compared to a…
  • p. 43 …More insight into this can be obtained from the distribution functions for trapped ions, sketched in…
  • p. 44 …The source to sink issue noted several times here can be explained as follows. Two opposite…
  • p. 47 …However, since the fusion core radius in these calculations is very small on the order of…
  • p. 49 …instability in finite spherical systems may be excited for small beam velocities compared to those of…
  • p. 50 …However, an experimental study should be performed to verify this result. RIDER - ENERGY BALANCE STUDY Todd…
  • p. 53 …In addition, since both D-D and D- 3He reactions can be used for proton production…
  • p. 54 …This can be viewed as a small scale soft source for individual laboratory studies such as…
  • p. 55 …The 14.1-MeV neutrons from the D-T reaction will be the primary source for…
  • p. 59 …Due to their small size, they can be used in a large array along with TOF…
  • p. 65 …If vis large compared to v11, the effective scattering angle will be large, resulting in retrapping…
  • p. 67 …Fortunately, the IEC can be scaled up in energy gain while keeping a small size since…
  • p. 68 …The small size of the IEC is a key characteristic. If rapid development is to be…
  • p. 71 …In other words, this could also be thought of as a Q=100 DT equivalent breakeven…
UNCLASSIFIED/ ff81il 8PPll!ltllt t!l91!! SHL'I'
events take place. Accordingly, he predicted that the Q-value (defined the ratio of
fusion power out to ion input power) of an IEC device operating with a 50/50 percent
deuterium-tritium (D-T) mixture would be ~0.21 for a 50-kV square well. This
conclusion would rule out the possibility of a fusion reactor, but would leave open the
development of driven neutron sources. However, this analysis contains several
questionable assumptions. For example, a tightly focused monoenergetic ion beam is in
fact a pessimistic scenario, because different co-moving ion species (such as D and T
with the same energy) result in a finite speed difference, thus fostering ion-ion
collisions and the degradation of the ion distribution function. It would be more realistic
to consider that, in a square well, friction between species would homogenize the speed
within the ion beam a~er some time, making the speed difference infinitesimal. This
line of argument was pursued earlier by Barnes et al., (Reference 4.3) who found Q ~
1. 3 for the same system.
ION INJECTION PORT
Ion extraction grid
Ion divertor
Pseudo-spherical
well for ion confinement
a
Electron divertor
I
E=Emax
E=Eo
Anode wall (ground)
Figure 4.2. Detail of the Anode and the Ion Injection Port in PFX-I (not to scale). Ion
and electron divertors are indicated, as well as the Eo and Ern" equipotential lines that define the
ion confinement region. The Eo contour line determines the region of absolute ion confinement.
In Chacon's work, a bounce-averaged Fokker-Planck (BAFP) model was employed to
obtain steady-state solutions for the ion distribution function and to calculate associated
fusion energy gains (Q-values) in a variety of operating conditions. These is done in
terms of source and sink strengths, ion injection energies, well depths, and electrostatic
potential shapes. Thus, the limiting assumptions by Nevins- namely that ions are
confined in a square potential well, and that their distribution is tightly focused and
monoenergetic, are relaxed. When these restrictive assumptions are removed, it is
found that large energy gains (Qs of hundreds) for beam-like solutions in square wells
35