Documents / Report

Defense Intelligence Reference Document Inertial Electrostatic Confinement Fusion

Defense Intelligence Agency · 72 pages · text from the file's own layer

This Defense Intelligence Agency reference document, dated 10 March 2010, covers inertial electrostatic confinement (IEC) fusion. It was produced in FY 2009 under the DIA's Advanced Aerospace Weapon System Applications (AAWSA) program. The report focuses on work at the University of Illinois Urbana-Champaign and reviews IEC basics, experiments, theory and applications such as neutron sources, explosives detection and space propulsion. It concludes by proposing a breakeven experiment for p-11B fusion that uses a hydrogen plasma simulation.

  • p. 7 …Emphasis is placed on work in these areas at the University of Illinois Urbana-Champaign, although…
  • p. 8 …of how inertial electrostatic confinement (IEC) fusion works. Gas ~ccd I in~ Spherical Vacuum . Chamber !!1…
  • p. 10 …While Hirsh worked with Farnsworth to demonstrate early experimental success with IEC experiments (Reference 1.2…
  • p. 11 …Such work was soon taken up in several other laboratories, including Los Alamos National Laboratory (LANL…
  • p. 12 …electron) injected traps (as does the present author's work). This selection was largely driven by…
  • p. 15 …This work and others on the small gridded systems at that time showed several important problems…
  • p. 17 …Recent work has shown that by properly programming the distribution function of the injected electrons it…
  • p. 18 …Results indicate that although the formalism works well during the early phases of compression, when the…
  • p. 21 …Hirsch Working With Philo Farnsworth I' I'· 0 ,,, 10•u w "',. ~ 40~ CRONS D- -,C •~7…
  • p. 22 …This worked well, but the design was eventually discarded to move to RF guns with much…
  • p. 23 …This work substituted a metallic hybrid getter for the external pumping on the IEC chamber. With…
  • p. 24 …Another important example of the use of a compact IEC neutron source is the work at…
  • p. 25 …2.7) The IEC developed for this work used a magnetron ion generation technique to improve…
  • p. 26 …Still the design worked reasonably well for the initial mine detection experiments. Unfortunately, the project was…
  • p. 27 …as shown by the hybrid magnetron source work in Japan. Another point noted is the advantage…
  • p. 29 …As already noted, the basic physics of this version was originally studied in pioneering work by…
  • p. 30 …Relation to Other Prior Thrusters NASA and other laboratories have worked toward developing advanced Hall Thrusters…
  • p. 31 …Indeed, the thruster concept arose from work on a fusion based IEC (Reference 3.5). To…
  • p. 32 …Khachan's work. It too looks very promising. 25 UNCLASSIFIED/ ,u;oAt OFFIGIPk IP&'i OIIU{
  • p. 35 …at the UIUC and several other laboratories working on IECs. The issue then is how to…
  • p. 39 …In follow-on work, they simplified the modeling of charge exchange with an analytical approach to…
  • p. 40 …Satsangi, "Inertial Electrostatic Confinement Experiments at Low Working Pressure," Prepared under U.S. Army contract DAAK…
  • p. 42 …In Chacon's work, a bounce-averaged Fokker-Planck (BAFP) model was employed to obtain steady…
  • p. 45 …Before discussing this work, some definitions for the potential well structure will be reviewed. POTENTIAL WELL…
  • p. 48 …However, much more work needs to be done along these lines to fully identify the optimal…
  • p. 52 …As pointed out by Khachan his work noted D2+ becomes more significant in lower voltages). In…
  • p. 53 …Nevins, Can inertial electrostatic confinement work beyond the ion-ion collisional time scale?" Phys. Plasmas, Vol…
  • p. 70 …Chacon's work, thermalized ions build up and additional quasi- Maxwellian distriution in the trap). Still…
  • p. 71 …To accomplish this result quickly on a modest budget, we need to simplify the work by…
UNCLASSIFIED/,Sf81il 8ffll!ltllt ~!II!! SHL'I'
In 1997 Miley and his group published
an IEEE paper that summarized their
internal ion injected grid experiments
(Reference 2.3). (As noted earlier "ion
injected" has been used to define the
species forming a potential well. It is not
to be confused with external "gun"
injection where ions form the well, but
are introduced from an external source).
It discusses the discharge physics and
plasma characteristics for various modes
of operation. It explains how the STAR
mode is created by the defocusing
properties concave inward (towards the
center core) in open grid structures.
Indeed the concept is somewhat anti-
intuitive since one might hope for
focusing "optics", but this is not possible
in these configurations. (Indeed various
multi-grid approaches have been studied
with the objective of improving beam
optics for reflection of ions, hence
recirculation. See for example, Reference
2.4. When ions pass through the
concave potential, all but those in the
Figure 2.3. Photograph of a STAR mode discharge.
The "vane" type grid shown 1s only one of a number of
large opening grids designed and used for STAR mode
operation of the neutron source type IEC. This particular
design (but with variations) has been used by the UIUC,
Daimler-Chrysler and Kyoto University. It is rugged,
shows little sputtering and has proven very efficient for
neutron production. Materials used vary from stainless
steel to Mo.
exact center of the curved surface are deflected and lost. The centered ions pass
through to the opposite side and go through the grid opening, then are reflected and
repeat this trajectory. Subsequently ionization events along this path cause a rapid
increase in the recirculating current through the center of the grid openings. This then
produces the beautiful STAR mode discharge shown in Figure 2.3.
The use of a pulsed power supply represents a very important way to study the physics
of high current IECs without employing expensive, very large power supplies and also
avoiding the need for strong cooling to remove the waste heat. The key physics point is
that the beam-beam fusion rate scales as the ion current squared. Most steady state
experiments employ 100s of mA, while pulsing peak values of many amps are possible.
By selecting the pulse width to match or exceed the ion confinement time, typically
order of ms in present devices, a quasi equilibrium is established during the pulse. This
allows study of "equivalent" steady-state physics during the pulse.
Miley's device in Reference 2.6 used a Marx bank technology to provide peak currents
of 10's of amps with a ~0.1 sec width and a low repetition rate (selected to minimize
cooling requirements and also reduce bank recharging requirements).
Another important technology regarding the IEC vessel pumping was developed in the
mid-1990s by staff from Miley's group working at the Idaho National Environmental and
Engineering Laboratory (!NEEL), Idaho with Robert A. Anderl (Reference 2.5). This work
substituted a metallic hybrid getter for the external pumping on the IEC chamber. With
this arrangement, the deuterium is absorbed in the getter material while the vapor
pressure, hence chamber background pressure, is controlled by regulation of the getter
16
UNCLASSIFIED//FQII. QFFlliil,t k llili O•lk¥

Not linked to a story yet.

About this file