Documents / Report

Defense Intelligence Reference Document High-Frequency Gravitational Wave Communications

Defense Intelligence Agency · 57 pages · text from the file's own layer

This Defense Intelligence Reference Document was prepared by the Defense Intelligence Agency under its Advanced Aerospace Weapon System Applications (AAWSA) program, is dated 6 April 2010 and is part of a series of advanced technology reports produced in FY 2009. It reviews proposed laboratory generators and detectors of high-frequency gravitational waves for communications. It favors an infrared-excited molecules transmitter and the Li-Baker detector, estimating about 1.9 million bits per second over 7,000 km through the Earth. It also discusses timing standards and interplanetary navigation uses.

  • p. 5 …with the advantage that they cannot be shielded or shadowed by planetary masses. Plasma interference seen…
  • p. 21 …The PPF signal can be intercepted by electromagnetic-interference-shielded microwave receivers located on the x…
  • p. 25 …High-sensitivity shielded microwave receivers are located at each end of the x-axis each about…
  • p. 37 …for solar monitoring, whereas L2 is permanently shielded from the sun. 4.0 Future Potential 4…
  • p. 38 …being able to pierce the protective plasma shielding that may in the future be routinely used…
  • p. 39 …aid for interplanetary missions (with no planetary shielding) by mapping geoids in interplanetary space via long…
UNCLASSIFIED/ ,'l"e" Cl"l"!e!•t tl9E CHE I
beam is much greater than the stored magnetic field energy, and it follows that E ::::ERF
= 10 11 J to a reasonable approximation.
Sources of Quality Factor and Effect on SQL
To calculate the SQL, hdet, we also need the value of the detector quality factor Q (not
the same as the cavity quality factor). Anything that concentrates or enhances the
signal preferentially over noise, in any measurement dimension, can be considered a
contributor to the quality factor Q. The quality factor can therefore be understood as
the "signal selectivity" in each dimension, so that
Qtot = ( Qspatia/) (Qt) = QrQsolid angieQt . (9)
The temporal quality factor in the Li-Baker detector arises from averaging the signal
over time, so that at 10 GHz, Qt= fltint = (10x10 9 Hz) x 1000s = 1013 .
There is a contribution to Q arising from the fractal membranes that focus and
concentrate the signal photon energy - but not the background photons - along the
radial dimension. The radial selectivity arising from the general relativity solution, in
conjunction with fractal membranes, is calculated by Li et al. (2008). Their table III
gives Qr= SNRrr~37cmJ/5NRrr~3.scmJ = 3.4x10 21 .
This is mostly due to the effective Q contribution arising from the synchro-resonance
solution to the Einstein field equations that limit the PPF signal to a radiation pattern in
certain directions, whereas noise is distributed uniformly. By utilizing directional
antennas, the Li-Baker detector can capitalize upon this gain due to the focusing power
of fractal membranes as a contribution to Q in angular space as well. This is calculated
in detail, octant by octant, by Li et al. (2008). Page 24 of Li et al. summarizes this in
terms of angular concentration onto the detector. A non-directional antenna
corresponds roughly to solid angle 2ff steradians ( one hemisphere), so that the effective
antenna gain is estimated as (Qso1idang1e) = 2rr sr/10. 4sr = 6.3x10 4 . Therefore, the
predicted maximum quality factor will be Qtotat = QrQsotidangteQt = 2.1x1039 . This finally
gives the Standard Quantum Limit (SQL) for stochastic GW detection at 10 GHz:
hdet = (1/Q) 112 (floJ/E) 112 = 1.8x10- 37 m/m . ( 10)
Comparison of SOL With Predicted Sensitivity
As noted in the previous section, hdet = 1.8x10- 37 m/m represents the lowest possible
GW amplitude detectable by each RF receiver in the Li-Baker HFGW detector, limited by
quantum back-action. An additional ( 1;-,/2) factor applies if the separate outputs from
the two RF receivers are averaged, rather than used independently for false alarm
reduction, resulting in a minimum hdet = l.2x10-37 . Since the predicted best sensitivity
of the Li-Baker detector in its currently proposed configuration is A= 10-32 m/m, these
results confirm that the Li-Baker Detector is photon-signal limited, not quantum noise
limited; that is, the Standard Quantum Limit is so low that a properly designed Li-Baker
detector can have sufficient sensitivity to observe HFRGW of amplitude A== 10-32 m/m.
19
UNCLASSIFIED//r;Oll oi;i;1,;;1•k llili O•lk¥

Not linked to a story yet.

About this file

Report, from the dia collection. The PDF is mirrored here; the original link is under it. 57 pages are in the text index: search them above, or from the library's search.