Documents / Report

Defense Intelligence Reference Document High-Frequency Gravitational Wave Communications

Defense Intelligence Agency · 57 pages · text from the file's own layer

This Defense Intelligence Reference Document was prepared by the Defense Intelligence Agency under its Advanced Aerospace Weapon System Applications (AAWSA) program, is dated 6 April 2010 and is part of a series of advanced technology reports produced in FY 2009. It reviews proposed laboratory generators and detectors of high-frequency gravitational waves for communications. It favors an infrared-excited molecules transmitter and the Li-Baker detector, estimating about 1.9 million bits per second over 7,000 km through the Earth. It also discusses timing standards and interplanetary navigation uses.

  • p. 5 …communications are carried on an extremely narrow beam directly through the Earth, there is a very…
  • p. 9 …Alternatively, a pulsed particle beam, which could include antimatter, could trigger nuclear reactions and build up…
  • p. 15 …Thus a HFGW total flux of l .29x 108 wm· 2 in a very narrow beam…
  • p. 16 …With this configuration, the width of the needle-like, narrow HFGW beam at the receive end…
  • p. 17 …The Birmingham University HFGW detector measures changes in the polarization state of a microwave beam (indicating…
  • p. 19 …The result of the intersection of the parallel and superimposed EM and GW beams, according to…
  • p. 20 …However, with the Li-Effect, there is an additional focused microwave beam ("Gaussian beam") at the…
  • p. 21 …The signal (the PPF) and the noise, or background photon flux (BPF) from the Gaussian beam…
  • p. 23 …Assuming a "best efforts" value of 1000 W for the power of the Gaussian beam in…
  • p. 24 UNCLASSIFIED/ ,'l"e" Cl"l"!e!•t tl9E CHE I beam is much greater than the…
  • p. 25 …A Gaussian (focused, with minimal side lobes) microwave beam (GB) is aimed along the +z-axis…
  • p. 30 …With this configuration, the width of the needle-like, narrow HFGW beam at the receive end…
  • p. 38 …with stronger magnetic fields, more intense Gaussian beams, and better baffles as well as new detector…
  • p. 46 …and Zhao P. (1992), "Interaction Between Narrow Wave Beam-Type High Frequency Gravitational Radiation and Electromagnetic…
  • p. 47 …M Land Fang Z. (2007), "Coupling of an open cavity to a microwave beam: a possible…
  • p. 52 …D01.3 Microwave Transmitter {Gaussian beam) Design of the microwave transmitter for the Gaussian beam, directed…
  • p. 53 …of the interior baffles around the Gaussian beam, and a "tunnel" between fractal-membrane reflectors and…
UNCLASSIFIED/ ,'l"e" Cl"l"!e!•t tl9E CHE I
beam is much greater than the stored magnetic field energy, and it follows that E ::::ERF
= 10 11 J to a reasonable approximation.
Sources of Quality Factor and Effect on SQL
To calculate the SQL, hdet, we also need the value of the detector quality factor Q (not
the same as the cavity quality factor). Anything that concentrates or enhances the
signal preferentially over noise, in any measurement dimension, can be considered a
contributor to the quality factor Q. The quality factor can therefore be understood as
the "signal selectivity" in each dimension, so that
Qtot = ( Qspatia/) (Qt) = QrQsolid angieQt . (9)
The temporal quality factor in the Li-Baker detector arises from averaging the signal
over time, so that at 10 GHz, Qt= fltint = (10x10 9 Hz) x 1000s = 1013 .
There is a contribution to Q arising from the fractal membranes that focus and
concentrate the signal photon energy - but not the background photons - along the
radial dimension. The radial selectivity arising from the general relativity solution, in
conjunction with fractal membranes, is calculated by Li et al. (2008). Their table III
gives Qr= SNRrr~37cmJ/5NRrr~3.scmJ = 3.4x10 21 .
This is mostly due to the effective Q contribution arising from the synchro-resonance
solution to the Einstein field equations that limit the PPF signal to a radiation pattern in
certain directions, whereas noise is distributed uniformly. By utilizing directional
antennas, the Li-Baker detector can capitalize upon this gain due to the focusing power
of fractal membranes as a contribution to Q in angular space as well. This is calculated
in detail, octant by octant, by Li et al. (2008). Page 24 of Li et al. summarizes this in
terms of angular concentration onto the detector. A non-directional antenna
corresponds roughly to solid angle 2ff steradians ( one hemisphere), so that the effective
antenna gain is estimated as (Qso1idang1e) = 2rr sr/10. 4sr = 6.3x10 4 . Therefore, the
predicted maximum quality factor will be Qtotat = QrQsotidangteQt = 2.1x1039 . This finally
gives the Standard Quantum Limit (SQL) for stochastic GW detection at 10 GHz:
hdet = (1/Q) 112 (floJ/E) 112 = 1.8x10- 37 m/m . ( 10)
Comparison of SOL With Predicted Sensitivity
As noted in the previous section, hdet = 1.8x10- 37 m/m represents the lowest possible
GW amplitude detectable by each RF receiver in the Li-Baker HFGW detector, limited by
quantum back-action. An additional ( 1;-,/2) factor applies if the separate outputs from
the two RF receivers are averaged, rather than used independently for false alarm
reduction, resulting in a minimum hdet = l.2x10-37 . Since the predicted best sensitivity
of the Li-Baker detector in its currently proposed configuration is A= 10-32 m/m, these
results confirm that the Li-Baker Detector is photon-signal limited, not quantum noise
limited; that is, the Standard Quantum Limit is so low that a properly designed Li-Baker
detector can have sufficient sensitivity to observe HFRGW of amplitude A== 10-32 m/m.
19
UNCLASSIFIED//r;Oll oi;i;1,;;1•k llili O•lk¥

Not linked to a story yet.

About this file

Report, from the dia collection. The PDF is mirrored here; the original link is under it. 57 pages are in the text index: search them above, or from the library's search.