Documents / Report

Defense Intelligence Reference Document Concepts For Extracting Energy From The Quantum Vacuum

Defense Intelligence Agency · 57 pages · text from the file's own layer

This Defense Intelligence Reference Document from the Defense Intelligence Agency, dated 6 April 2010, is one in a series of FY 2009 advanced technology reports produced under the Advanced Aerospace Weapon System Applications (AAWSA) program. It reviews the physics of zero-point field energy in the quantum vacuum and proposed schemes for extracting it, including the Casimir effect, Forward's vacuum-fluctuation battery, and resonant dielectric spheres. It notes that no practicable extraction technique has been demonstrated in the laboratory.

  • p. 7 …A "vacuum- fluctuation battery" can be constructed by using the Casimir force to do work on…
  • p. 8 …Moreover, work can be done by or done on physical systems, either at T = O or…
  • p. 9 …AFB, CA) indicates that the invention could work, no experimental study has been performed to validate…
  • p. 10 …8FFll!l*L 1!1!11! t!IIU:!Y might work, it is necessary to characterize…
  • p. 12 …The formulation of the SED model has evolved over time, beginning with the work of Nernst…
  • p. 13 …proves that the ZPF can do real work (cause measurable currents). Although the Koch et al…
  • p. 23 …This comports with the first reason, and indicates that more theoretical and experimental work is needed…
  • p. 32 …is not conserved during cosmological expansion, with work being done by the negative vacuum pressure to…
  • p. 33 …Though further work remains, these considerations lead one to conclude that SED in its present form…
  • p. 38 …Substantial theoretical and experimental work has shown that in many quantum systems the limits to measurement…
UNCLASSIFIED/ }F81il 8FFI1il.t.k Wfili &,.kY
:::: 10 times the weight of the Casimir plates, and so forth), an estimate of the
achievable power might be obtained. Based on the described parameters, and assuming
a switching from a purely conductive state to a dielectric constant of K = 4, yields a
figure of merit of,,, 35 x f(MHz) W/kg (f = switching rate) for the power density
(Reference 29). This can be compared to the power density of:::: 5 W/kg achieved by
current radioisotope thermoelectric generators. The predicted output power per unit
area for this experimental device is"" 10-6 f(MHz)/4[d(μm)P W/cm 2 .
Spacing. d (μ,n)
0.5 0.6 0.7 0.8 0.9 1.0
0
_......___ronclurtor
-·--e~ m
t-
30
Figure 9. Tunable Casimir Effect: Conductor vs. Dielectric
15
UNCLASSIFIED/ ,'Pett err1e1111t ~:!I! 9HLY

Not linked to a story yet.

About this file

Report, from the dia collection. The PDF is mirrored here; the original link is under it. 57 pages are in the text index: search them above, or from the library's search.